Challenges and mitigation measures in power systems with high share of renewables—the Australian experience
F Arraño-Vargas, Z Shen, S Jiang, J Fletcher, G Konstantinou
Energies 15 (2), 429, 2022
532022
Self-circulating testing method for both rectifying and inverting submodules of modular multilevel converter with low DC supply voltage
S Jiang, K Ma, X Cai
IEEE Transactions on Power Electronics 35 (8), 7795-7803, 2019
282019
A fault location method for DC lines connected with DAB terminal in power electronic transformer
S Jiang, C Fan, N Huang, Y Zhu, M He
IEEE Transactions on Power Delivery 34 (1), 301-311, 2018
282018
Fault Characteristic Analysis of DC Pole-to-Pole Fault in Power Electronic Transformer
S JIANG, C FAN, N HUANG, J ZENG
Proceedings of the CSEE 38 (5), 1301 - 1309, 2018
21*2018
Settling Angle-Based Stability Criterion for Power-Electronics-Dominated Power Systems
S Jiang, Y Zhu, G Konstantinou
IEEE Transactions on Power Electronics 38 (3), 2972-2984, 2023
202023
Settling-angle-based stability analysis for multiple current-controlled converters
S Jiang, Y Zhu, G Konstantinou
IEEE Transactions on Power Electronics 37 (11), 12992-12997, 2022
182022
Mission profile emulator for individual submodule in modular multilevel converter with nearest level control
S Jiang, K Ma, Y Yang, X Cai
IEEE Transactions on Power Electronics 36 (9), 9722-9730, 2021
182021
Three-phase mission profile emulator for multiple submodules in modular multilevel converter
K Ma, S Jiang, E Li, X Cai
IEEE Transactions on Power Electronics 36 (5), 5213-5222, 2020
172020
Generalized impedance model and interaction analysis for multiple grid-forming and grid-following converters
S Jiang, G Konstantinou
Electric Power Systems Research 214, 108912, 2023
152023
Mission Profile Emulation for Flexible Number of Submodules in Modular Multilevel Converters with Nearest Level Modulation
S Jiang, K Ma, X Cai, G Konstantinou
IEEE Transactions on Industrial Electronics 69 (12), 11926 - 11935, 2021
152021
Fault protection scheme for DC distribution network based on ratio of transient voltage principle
S Wang, C Fan, S Jiang
Dianli Zidonghua Shebei/Electric Power Automation Equipment 40 (7), 196-203, 2020
12*2020
Fault location in low‐voltage direct current network based on auxiliary injection unit
S Jiang, C Fan, N Huang
IET Generation, Transmission & Distribution 13 (19), 4347-4354, 2019
102019
Impedance-based stability analysis: Nodal admittance or bus admittance?
S Jiang, G Konstantinou
IEEE Transactions on Power Systems, 2023
92023
Mitigation of power system oscillations in weak grids with battery energy storage systems: A real-world case study
F Arraño-Vargas, S Jiang, B Bennett, G Konstantinou
Energy 283, 128648, 2023
62023
Calculation of Current Protection Setting Based on Inverter Generation Control Strategy
S Jin, Y Song, C Fan, S Jiang, X Li
Dianwang Jishu/Power System Technology 45 (9), 3690 - 3699, 2021
6*2021
An accurate analysis method for transient characteristics of DC line faults in voltage source converter‐based DC systems
Z Xiao, X Zheng, Y He, N Tai, C Fan, N Huang, S Jiang
IET Generation, Transmission & Distribution 15 (4), 589-601, 2021
62021
Stability-oriented multi-objective control design for power converters assisted by deep reinforcement learning
S Jiang, Y Zeng, Y Zhu, J Pou, G Konstantinou
IEEE Transactions on Power Electronics, 2023
32023
Coordination Method Between AC and DC Protections Based on DC Side 100Hz Component
N Huang, C Fan, S Jiang, J Su, G Li, S Sun
Dianwang Jishu/Power System Technology 43 (11), 4150 - 4159, 2019
3*2019
Research of protection for AC transmission lines based on characteristic of grid‐side inverter
N Huang, C Fan, S Jiang
The Journal of Engineering 2019 (16), 3240-3245, 2019
32019
Three-phase test bench for multiple submodules in modular multilevel converter system
S Jiang, K Ma, Y Zhu
2019 IEEE Energy Conversion Congress and Exposition (ECCE), 2252-2256, 2019