Folgen
Matias de la Fuente
Matias de la Fuente
Bestätigte E-Mail-Adresse bei hia.rwth-aachen.de - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Assessment of optical localizer accuracy for computer aided surgery systems
R Elfring, M de la Fuente, K Radermacher
Computer Aided Surgery 15 (1-3), 1-12, 2010
1572010
Statistical validation metric for accuracy assessment in medical image segmentation
A Popovic, M De la Fuente, M Engelhardt, K Radermacher
International Journal of Computer Assisted Radiology and Surgery 2, 169-181, 2007
1242007
A high-resolution head-related transfer function and three-dimensional ear model database
R Bomhardt, M de la Fuente Klein, J Fels
Proceedings of Meetings on Acoustics 29 (1), 2016
772016
Simplified detection of myocardial ischemia by seismocardiography
M Becker, AB Roehl, U Siekmann, A Koch, M De La Fuente, R Roissant, ...
Herz 39 (5), 586, 2014
432014
Toward versatile cooperative surgical robotics: a review and future challenges
P Schleer, S Drobinsky, M de la Fuente, K Radermacher
International Journal of Computer Assisted Radiology and Surgery 14, 1673-1686, 2019
392019
Fluoroscopic navigation system for hip surface replacement
P Belei, A Skwara, MDL Fuente, E Schkommodau, S Fuchs, DC Wirtz, ...
Computer Aided Surgery 12 (3), 160-167, 2007
392007
System for positioning a surgical device
S Lavallee, M De la Fuente Klein, K Radermacher, A Niesche, M Muller, ...
US Patent 10,368,878, 2019
312019
Fluoroscopy-based 3-D reconstruction of femoral bone cement: A new approach for revision total hip replacement
M De La Fuente, JAK Ohnsorge, E Schkommodau, S Jetzki, DC Wirtz, ...
IEEE transactions on biomedical engineering 52 (4), 664-675, 2005
292005
In-vitro cell treatment with focused shockwaves—influence of the experimental setup on the sound field and biological reaction
K Dietz-Laursonn, R Beckmann, S Ginter, K Radermacher, M de la Fuente
Journal of therapeutic ultrasound 4, 1-14, 2016
262016
System for the treatment of a planned volume of a body part
S Lavallee, M De la Fuente Klein, K Radermacher, A Niesche, M Muller, ...
US Patent 10,441,294, 2019
252019
Myocardial effects of local shock wave therapy in a Langendorff model
M Becker, A Goetzenich, AB Roehl, C Huebel, M de la Fuente, ...
Ultrasonics 54 (1), 131-136, 2014
252014
Line-and point-focused extracorporeal shock wave therapy for Achilles tendinopathy: a placebo-controlled RCT study
M Gatz, S Schweda, M Betsch, T Dirrichs, M de la Fuente, N Reinhardt, ...
Sports Health 13 (5), 511-518, 2021
242021
Device for controlled adjustment of a surgical positioning unit
M De la Fuente Klein, P Belei, K Radermacher, A Boyer, S LaVallee
US Patent 8,974,460, 2015
222015
Calculation of impingement-free combined cup and stem alignments based on the patient-specific pelvic tilt
J Hsu, M de la Fuente, K Radermacher
Journal of Biomechanics 82, 193-203, 2019
202019
Exposure of zebra mussels to extracorporeal shock waves demonstrates formation of new mineralized tissue inside and outside the focus zone
K Sternecker, J Geist, S Beggel, K Dietz-Laursonn, M de la Fuente, ...
Biology open 7 (7), bio033258, 2018
152018
Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws. A cadaver study
MC Müller, P Belei, M De La Fuente, M Strake, O Weber, C Burger, ...
Computer Aided Surgery 16 (1), 22-31, 2011
152011
A robust method for automatic identification of femoral landmarks, axes, planes and bone coordinate systems using surface models
MCM Fischer, SAGA Grothues, J Habor, M de la Fuente, K Radermacher
Scientific Reports 10 (1), 20859, 2020
142020
Non-invasive measurement of muscle compartment elasticity in lower limbs to determine acute compartment syndrome: Clinical results with pressure related ultrasound
RM Sellei, J Wollnitz, N Reinhardt, M de la Fuente, K Radermacher, ...
Injury 51 (2), 301-306, 2020
142020
Trackerless ultrasound-integrated bone cement detection using a modular minirobot in revision total hip replacement
S Heger, M Niggemeyer, M de la Fuente, T Mumme, K Radermacher
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2010
132010
A-mode ultrasound-based intra-femoral bone cement detection and 3D reconstruction in RTHR
S Heger, T Mumme, R Sellei, MDL Fuente, DC Wirtz, K Radermacher
Computer Aided Surgery 12 (3), 168-175, 2007
112007
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20