Follow
Siegfried Wassertheurer
Siegfried Wassertheurer
Dept. Health & Environment, Austrian Institute of Technology
Verified email at ait.ac.at
Title
Cited by
Cited by
Year
Validation of a brachial cuff-based method for estimating central systolic blood pressure
T Weber, S Wassertheurer, M Rammer, E Maurer, B Hametner, CC Mayer, ...
Hypertension 58 (5), 825-832, 2011
5262011
A new oscillometric method for pulse wave analysis: comparison with a common tonometric method
S Wassertheurer, J Kropf, T Weber, M Van Der Giet, J Baulmann, ...
Journal of human hypertension 24 (8), 498-504, 2010
4422010
Noninvasive determination of carotid–femoral pulse wave velocity depends critically on assessment of travel distance: a comparison with invasive measurement
T Weber, M Ammer, M Rammer, A Adji, MF O'Rourke, S Wassertheurer, ...
Journal of hypertension 27 (8), 1624-1630, 2009
3532009
Oscillometric estimation of aortic pulse wave velocity: comparison with intra-aortic catheter measurements
B Hametner, S Wassertheurer, J Kropf, C Mayer, B Eber, T Weber
Blood pressure monitoring 18 (3), 173-176, 2013
3392013
Establishing reference values for central blood pressure and its amplification in a general healthy population and according to cardiovascular risk factors
A Herbert, JK Cruickshank, S Laurent, P Boutouyrie
European heart journal 35 (44), 3122-3133, 2014
3292014
Learning performance with interactive simulations in medical education: Lessons learned from results of learning complex physiological models with the HAEMOdynamics SIMulator
A Holzinger, MD Kickmeier-Rust, S Wassertheurer, M Hessinger
Computers & Education 52 (2), 292-301, 2009
2572009
Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization
JE Sharman, AP Avolio, J Baulmann, A Benetos, J Blacher, CL Blizzard, ...
European heart journal 38 (37), 2805-2812, 2017
2302017
Wave Reflections, Assessed With a Novel Method for Pulse Wave Separation, Are Associated With End-Organ Damage and Clinical Outcomes
T Weber, S Wassertheurer, M Rammer, A Haiden, B Hametner, B Eber
Hypertension 60 (2), 534-541, 2012
2282012
Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies
TG Papaioannou, TD Karageorgopoulou, TN Sergentanis, AD Protogerou, ...
Journal of hypertension 34 (7), 1237-1248, 2016
1552016
Pulsatile hemodynamics in patients with exertional dyspnea–potentially of value in the diagnostic evaluation of suspected heart failure with preserved ejection fraction
T Weber, S Wassertheurer, MF O'Rourke, A Haiden, R Zweiker, ...
Journal of the American College of Cardiology 61 (18), 1874 - 1883, 2013
1352013
Noninvasive methods to assess pulse wave velocity: comparison with the invasive gold standard and relationship with organ damage
T Weber, S Wassertheurer, B Hametner, S Parragh, B Eber
Journal of hypertension 33 (5), 1023-1031, 2015
1242015
Wave reflection quantification based on pressure waveforms alone—Methods, comparison, and clinical covariates
B Hametner, S Wassertheurer, J Kropf, C Mayer, A Holzinger, B Eber, ...
Computer methods and programs in biomedicine 109 (3), 250 - 259, 2012
1162012
Aortic pulse wave velocity predicts mortality in chronic kidney disease stages 2–4
M Baumann, S Wassertheurer, Y Suttmann, K Burkhardt, U Heemann
Journal of hypertension 32 (4), 899-903, 2014
1092014
Selection of entropy-measure parameters for knowledge discovery in heart rate variability data
CC Mayer, M Bachler, M Hörtenhuber, C Stocker, A Holzinger, ...
BMC bioinformatics 15, 1-11, 2014
1062014
Effect of monthly, high‐dose, long‐term vitamin D supplementation on central blood pressure parameters: a randomized controlled trial substudy
JD Sluyter, CA Camargo Jr, AW Stewart, D Waayer, CMM Lawes, L Toop, ...
Journal of the American Heart Association 6 (10), e006802, 2017
1022017
Reservoir and excess pressures predict cardiovascular events in high-risk patients
B Hametner, S Wassertheurer, AD Hughes, KH Parker, T Weber, B Eber
International journal of cardiology 171 (1), 31-36, 2014
982014
Modeling arterial and left ventricular coupling for non-invasive measurements
S Wassertheurer, C Mayer, F Breitenecker
Simulation modelling practice and theory 16 (8), 988-997, 2008
942008
Aortic pulse wave velocity predicts cardiovascular events and mortality in patients undergoing coronary angiography: a comparison of invasive measurements and noninvasive estimates
B Hametner, S Wassertheurer, CC Mayer, K Danninger, RK Binder, ...
Hypertension 77 (2), 571-581, 2021
842021
Assessment of central haemomodynamics from a brachial cuff in a community setting
D Nunan, S Wassertheurer, D Lasserson, B Hametner, S Fleming, A Ward, ...
BMC cardiovascular disorders 12, 1-9, 2012
792012
Assessment of systolic aortic pressure and its association to all cause mortality critically depends on waveform calibration
S Wassertheurer, M Baumann
Journal of hypertension 33 (9), 1884-1889, 2015
742015
The system can't perform the operation now. Try again later.