Folgen
Benjamin Csippa
Benjamin Csippa
Bestätigte E-Mail-Adresse bei hds.bme.hu
Titel
Zitiert von
Zitiert von
Jahr
Multiple aneurysms anatomy challenge 2018 (MATCH): phase I: segmentation
P Berg, S Voß, S Saalfeld, G Janiga, AW Bergersen, K Valen-Sendstad, ...
Cardiovascular engineering and technology 9, 565-581, 2018
802018
Multiple Aneurysms AnaTomy CHallenge 2018 (MATCH)—phase II: rupture risk assessment
P Berg, S Voß, G Janiga, S Saalfeld, AW Bergersen, K Valen-Sendstad, ...
International journal of computer assisted radiology and surgery 14, 1795-1804, 2019
482019
A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response
G Závodszky, B Csippa, G Paál, I Szikora
International Journal for Numerical Methods in Biomedical Engineering 36 (6 …, 2020
122020
A new hypothesis on the role of vessel topology in cerebral aneurysm initiation
B Csippa, G Závodszky, G Paál, I Szikora
Computers in Biology and Medicine 103, 244-251, 2018
92018
Nanonewton scale adhesion force measurements on biotinylated microbeads with a robotic micropipette
R Ungai-Salánki, B Csippa, T Gerecsei, B Péter, R Horvath, B Szabó
Journal of Colloid and Interface Science 602, 291-299, 2021
72021
The holistic coronary physiology display: calculation of the flow separation index in vessel-specific individual flow range during fractional flow reserve measurement using 3D …
GT Szabo, Á Üveges, B Tar, A Agoston, A Dorj, C Jenei, R Kolozsvari, ...
Journal of Clinical Medicine 10 (9), 1910, 2021
72021
Hydrodynamic resistance of intracranial flow-diverter stents: measurement description and data evaluation
B Csippa, D Gyürki, G Závodszky, I Szikora, G Paál
Cardiovascular engineering and technology 11, 1-13, 2020
72020
Simplified coronary flow reserve calculations based on three-dimensional coronary reconstruction and intracoronary pressure data
B Csippa, Á Üveges, D Gyürki, C Jenei, B Tar, B Bugarin-Horváth, ...
Cardiology Journal 30 (4), 516-525, 2023
42023
Pressure-and 3D-derived coronary flow reserve with hydrostatic pressure correction: comparison with intracoronary Doppler measurements
B Tar, A Ágoston, Á Üveges, GT Szabó, T Szűk, A Komócsi, D Czuriga, ...
Journal of Personalized Medicine 12 (5), 780, 2022
42022
Impact of design and deployment technique on the hydrodynamic resistance of flow diverters: an in vitro experimental study
D Gyürki, B Csippa, G Paál, I Szikora
Clinical Neuroradiology, 1-9, 2022
42022
Comparison of Manual versus Semi-Automatic Segmentations of the Stenotic Carotid Artery Bifurcation
B Csippa, Z Mihály, Z Czinege, MB Németh, G Halász, G Paál, ...
Applied Sciences 11 (17), 8192, 2021
32021
Decomposition of Velocity Field Along a Centerline Curve Using Frenet-Frames: Application to Arterial Blood Flow Simulations
B Csippa, L Sándor, G Paál
Periodica Polytechnica Mechanical Engineering 65 (4), 374-384, 2021
12021
Potential Clinical Usefulness of Post-Valvular Contrast Densities to Determine the Severity of Aortic Valve Stenosis Using Computed Tomography
AO Racz, GT Szabo, T Papp, B Csippa, D Gyurki, B Kracsko, Z Koszegi, ...
Journal of Cardiovascular Development and Disease 10 (10), 412, 2023
2023
Novel Method to Detect Pitfalls of Intracoronary Pressure Measurements by Pressure Waveform Analysis
C Jenei, B Tar, A Ágoston, P Sánta, J Sánta, B Csippa, R Wéber, D Gyürki, ...
Journal of Personalized Medicine 12 (12), 2035, 2022
2022
P10 Impact of secondary fluid motion and wall shear stress in sidewall aneurysm initiation
I Szikora, B Csippa, D Gyurki, M Kondor, M Czencz, A Vadasz, G Paal
Journal of NeuroInterventional Surgery 14 (Suppl 2), A13-A13, 2022
2022
419 The Effect Of Increased Flow In Aortic Stenosis On Paravalvular Contrast Densities-Correlation With Echocardiography Parameters In Focus
R Kolozsvari, A Racz, Z Koszegi, I Racz, P Tamas, B Csippa
Journal of Cardiovascular Computed Tomography 16 (4), S9-S10, 2022
2022
Impact of Design and Deployment Technique on the Hydrodynamic Resistance of Flow Diverters
G Dániel, C Benjamin, P György, S István
Clinical Neuroradiology 32 (1), 107-115, 2022
2022
Pressure-and 3D-derived coronary Flow Reserve with Hydrostatic Pressure Correction-A Validation by Intracoronary Doppler Measurements
B Tar, A Ágoston, Á Üveges, GT Szabó, T Szűk, A Komócsi, D Czuriga, ...
2021
Development of a Clamping Device for Tensile Testing of Intracranial Flow Diverter Stents
C Bukor, D Károly, B Csippa
Acta Materialia Transylvanica 4 (2), 83-86, 2021
2021
Impact of Design and Deployment Technique on the Hydrodynamic Resistance of Flow Diverters
D Gyürki, B Csippa, G Paál, I Szikora
2021
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20