Folgen
Kohnen Thomas, MD, PhD, FEBO
Kohnen Thomas, MD, PhD, FEBO
Professor and Chair, Department of Ophthalmology, Goethe University
Bestätigte E-Mail-Adresse bei em.uni-frankfurt.de
Titel
Zitiert von
Zitiert von
Jahr
Comparison of viscoelastic substances used in phacoemulsification
WW Hütz, BH Eckhardt, T Kohnen
Journal of Cataract & Refractive Surgery 22 (7), 955-959, 1996
18751996
European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens
T Kohnen, D Allen, C Boureau, P Dublineau, C Hartmann, E Mehdorn, ...
Ophthalmology 113 (4), 578-584. e1, 2006
4192006
Late in-the-bag intraocular lens dislocation: incidence, prevention, and management
HV Gimbel, GP Condon, T Kohnen, RJ Olson, I Halkiadakis
Journal of Cataract & Refractive Surgery 31 (11), 2193-2204, 2005
3782005
Comparison of the induced astigmatism after temporal clear corneal tunnel incisions of different sizes
T Kohnen, B Dick, KW Jacobi
Journal of Cataract & Refractive Surgery 21 (4), 417-424, 1995
2851995
Long-term endothelial cell loss following phacoemulsification through a temporal clear corneal incision
BH Dick, T Kohnen, FK Jacobi, KW Jacobi
Journal of Cataract & Refractive Surgery 22 (1), 63-71, 1996
2671996
Phakic intraocular lenses: part 2: results and complications
T Kohnen, D Kook, M Morral, JL Güell
Journal of Cataract & Refractive Surgery 36 (12), 2168-2194, 2010
2612010
Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm
L Wang, M Shirayama, XJ Ma, T Kohnen, DD Koch
Journal of Cataract & Refractive Surgery 37 (11), 2018-2027, 2011
2582011
Phakic intraocular lenses: part 1: historical overview, current models, selection criteria, and surgical techniques
JL Güell, M Morral, D Kook, T Kohnen
Journal of Cataract & Refractive Surgery 36 (11), 1976-1993, 2010
2172010
Format for reporting refractive surgical data
DD Koch, T Kohnen, SA Obstbaum, ES Rosen
Journal of Cataract & Refractive Surgery 24 (3), 285-287, 1998
2171998
Corneal architecture of femtosecond laser and microkeratome flaps imaged by anterior segment optical coherence tomography
B von Jagow, T Kohnen
Journal of Cataract & Refractive Surgery 35 (1), 35-41, 2009
2092009
Macular thickness after uneventful cataract surgery determined by optical coherence tomography
B von Jagow, C Ohrloff, T Kohnen
Graefe's Archive for Clinical and Experimental Ophthalmology 245, 1765-1771, 2007
2092007
Wavefront-guided LASIK with the Zyoptix 3.1 system for the correction of myopia and compound myopic astigmatism with 1-year follow-up: clinical outcome and change in higher …
T Kohnen, J Bühren, C Kühne, A Mirshahi
Ophthalmology 111 (12), 2175-2185, 2004
2022004
Defining subclinical keratoconus using corneal first-surface higher-order aberrations
J Bühren, C Kühne, T Kohnen
American journal of ophthalmology 143 (3), 381-389. e2, 2007
2002007
Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a+ 3.0 D addition
T Kohnen, R Nuijts, P Levy, E Haefliger, JF Alfonso
Journal of Cataract & Refractive Surgery 35 (12), 2062-2069, 2009
1922009
Tilt and decentration of spherical and aspheric intraocular lenses: effect on higher-order aberrations
M Baumeister, J Bühren, T Kohnen
Journal of Cataract & Refractive Surgery 35 (6), 1006-1012, 2009
1922009
Effect of temporal and nasal unsutured limbal tunnel incisions on induced astigmatism after phacoemulsification
S Kohnen, R Neuber, T Kohnen
Journal of Cataract & Refractive Surgery 28 (5), 821-825, 2002
1842002
Retrospective comparison of techniques to prevent secondary cataract formation after posterior chamber intraocular lens implantation in infants and children
DD Koch, T Kohnen
Journal of Cataract & Refractive Surgery 23, 657-663, 1997
1801997
Detection of subclinical keratoconus by using corneal anterior and posterior surface aberrations and thickness spatial profiles
J Bühren, D Kook, G Yoon, T Kohnen
Investigative ophthalmology & visual science 51 (7), 3424-3432, 2010
1782010
Comparison of manual and automated methods to determine horizontal corneal diameter
M Baumeister, E Terzi, Y Ekici, T Kohnen
Journal of Cataract & Refractive Surgery 30 (2), 374-380, 2004
1772004
Measuring contrast sensitivity under different lighting conditions: comparison of three tests
J Bühren, E Terzi, M Bach, W Wesemann, T Kohnen
Optometry and Vision Science 83 (5), 290-298, 2006
1742006
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20